Why Liquid Cooling for Edge Is Now Essential
Published on July 11, 2025,
by
Why Liquid Cooling for Edge Is Now Essential
As artificial intelligence (AI) and high-performance computing (HPC) continue to evolve, they are placing unprecedented demands on data center infrastructure, especially at the edge. One of the most urgent challenges in this space is thermal management. With server and rack power densities climbing rapidly, traditional cooling methods are being pushed to their limits. This is where liquid cooling for edge deployments becomes not just beneficial, but essential.
The Thermal Challenge at the Edge
Edge computing is all about bringing compute power closer to where data is generated—whether that’s in factories, retail stores, telecom towers, or remote industrial sites. But as AI workloads become more common at the edge, the power density of server racks is skyrocketing. While the industry average for rack power used to hover around 10 kW, it’s now moving toward 20 kW, with some AI-intensive deployments exceeding 40 kW and even approaching 100 kW per rack.
This level of heat generation is far beyond what traditional air-cooling systems were designed to handle. As a result, data center operators are being forced to rethink their approach to cooling—especially in edge environments where space, power, and maintenance resources are limited.
Advanced Air Cooling: Still Viable for Lower Densities
For edge deployments with lower power densities, advanced air-cooling strategies can still be effective. These include:
- Hot aisle/cold aisle containment: This method separates hot and cold airflows to prevent mixing and improve cooling efficiency.
- In-row and rack-level cooling: These systems deliver cold air directly to the equipment that needs it, reducing energy waste and improving performance.
However, once rack densities exceed the 20–30 kW threshold, air cooling becomes increasingly inefficient and unreliable. That’s when liquid cooling for edge becomes a necessity.
Why Liquid Cooling Is the Future
Liquid is thousands of times more effective at transferring heat than air. This makes it the only viable solution for managing the thermal output of modern, high-density processors and GPUs. There are three primary types of liquid cooling systems being adopted in edge and core data centers:
1. Rear Door Heat Exchangers (RDHx)
These systems attach to the back of a server rack and use chilled water to absorb heat from the air as it exits the rack. RDHx is relatively easy to retrofit into existing environments and provides a significant boost in cooling capacity without requiring major infrastructure changes.
2. Direct-to-Chip (DTC) Cooling
DTC systems circulate a liquid coolant directly over the hottest components—typically CPUs and GPUs—using sealed cold plates. This method removes heat at the source, making it ideal for AI workloads that generate intense, localized heat. DTC is a key enabler for deploying powerful AI hardware like NVIDIA’s H200 GPUs.
3. Immersion Cooling
The most aggressive and efficient form of liquid cooling, immersion cooling involves submerging entire servers in a non-conductive, dielectric fluid. This method can support extreme rack densities of up to 300 kW and offers up to 95% savings in cooling energy. While it requires specialized equipment and design, immersion cooling is gaining traction for the most demanding edge and core deployments.
The Shift from Theory to Reality
The adoption of liquid cooling for edge is no longer a theoretical discussion. It’s happening now. Data center operators are embracing these technologies as a competitive necessity to support AI workloads. But this shift has a ripple effect on how edge data centers are designed and deployed.
The choice of cooling system is now directly tied to the IT hardware being used. For example, selecting a specific GPU may dictate the type of cooling system, plumbing, and coolant distribution units (CDUs) required. This creates a complex interdependency between IT and facility infrastructure—one that is difficult to manage at scale, especially across distributed, unmanned edge sites.
Why Modularity Is the Key to Scalability
Trying to engineer and integrate these complex systems from scratch at each edge location is a recipe for failure. It’s slow, expensive, and introduces significant risk. That’s why the industry is moving toward prefabricated, modular solutions.
These modular systems are:
- Pre-engineered: Designed to meet the specific thermal and power requirements of high-density AI hardware.
- Pre-integrated: All components—servers, cooling, power, and networking—are built to work together seamlessly.
- Pre-validated: Tested in a factory environment to ensure reliability and performance before deployment.
By using modular infrastructure, organizations can deploy liquid cooling for edge environments quickly and reliably. This approach eliminates the guesswork and complexity of on-site integration and ensures that each site is optimized for the specific AI workloads it will support.
The Convergence of Trends
The move toward liquid cooling and the shift toward modular infrastructure are not separate trends—they are converging. Together, they represent a new standard for deploying high-performance edge computing environments.
As AI continues to drive up power densities, and as edge computing becomes more critical to business operations, organizations must adopt solutions that are both powerful and scalable. Liquid cooling for edge is no longer optional—it’s a foundational requirement for the next generation of data infrastructure.
Final Thoughts
The edge is evolving rapidly, and with it, the demands on infrastructure. Cooling is no longer just a support function—it’s a strategic enabler of performance, efficiency, and scalability. By embracing liquid cooling for edge and leveraging modular, prefabricated solutions, organizations can stay ahead of the curve and unlock the full potential of AI at the edge.